Projects

Projects

These are a few of the projects we have been involved in recently. We take great pride in our work and love to showcase our success. We have worked with a number of clients over the years on contracts of varying sizes, carrying out every project with a professional and versatile approach.

If you have a project you think we could help with, or would like to find out more about any of the installations below, get in touch and we can talk you through the process and give you a quote.

Client – Intuitive Surgical

Project Value – £230,000.00

Project Details – We were tasked with providing a full design & build electrical fit out of a CAT A ground floor office in the Schrodinger Building on Oxford Science Park.

The client was incredibly pleased with the finished article and so were we! Works included replacement of three phase distribution boards, LED feature lighting throughout, small power installation, fire alarm modifications, Salto door access system, intruder alarm system and CAT6 data installation.

Client - Total Projects Ltd

Project Value – £180,000.00

Project Details – CAT A design and build warehouse and office installation on Milton Park, Oxfordshire

  • LED lighting installation with presence/absence detection to cut energy costs
  • Open protocol fire alarm installation installed to a category L2 throughout the office and category M in the warehouse
  • Disabled refuge system installed to both units
  • Small power including floor boxes, underfloor containment installation and various power outlets
  • Installation of BREEAM compatible three section LV distribution boards to separately meter lighting, small power and mechanical DB’s
  • Mechanical power installed to ensure air conditioning and ventilation needs were met
View More Photos

Client – Oxford Immunotec

Project Value – £580,000.00

Project Details – Complete design and build laboratory and office installation on Milton Park, Oxfordshire

  • Smart LED lighting installation using Ligo lighting controls
  • Installation of a cloud based Brivo door access system
  • Intruder alarm system installed throughout linked to the Brivo system
  • Audio visual intercom system installed to link reception with the office area
  • Fire alarm installation installed to a category L2 throughout the office and laboratories
  • Small power including floor boxes, underfloor busbar installation and various power outlets
  • Installation of new 800A main panel as well as various LV distribution boards, liaising with the local DNO to provide an upgrade of supply
  • Mechanical power installed to ensure air conditioning and ventilation needs were met
  • Installation of cabling to ensure BMS system is linked to electrical items
View More Photos

Client – Oxford Space Systems

Project Value – £260,000.00

Project Details – Complete design and build warehouse and office installation on Harwell Campus, Oxfordshire

  • LED lighting installation with presence/absence detection to cut energy costs
  • Installation of a cloud based Paxton NET2 door access system
  • Honeywell Galaxy Intruder alarm system installed which was connected to a RedCare grade 2 system response
  • GENT Vigilon Fire alarm installation installed to a category L2 throughout the office and warehouse
  • Audio visual intercom system installed to link the offices to reception
  • Installation of a new CCTV 16 channel system
  • Small power including floor boxes, underfloor containment installation and various power outlets
  • Installation of new 800A main panel as well as various LV distribution boards
  • Mechanical power installed to ensure air conditioning and ventilation needs were met
View More Photos

Client – Critchleys

Project Value – £85,000.00

Project Details – Complete design and build office refurbishment carried out in the middle of Oxford City Centre

  • LED lighting installation with presence/absence detection to cut energy costs
  • Audio visual installation that included ceiling projectors, surround sound and remote control screens
  • Door access system installed to create a safe server room
  • Fire alarm installation installed to a category L2 throughout the office
  • Small power including floor boxes, underfloor busbar alterations and various power outlets
  • Mechanical power installed to ensure air conditioning and ventilation needs were met
View More Photos

Client – Infor (London)

Project Value – £75,000.00

Project Details – Complete design and build office refurbishment carried out on the 11th floor of Victoria Street, Westminster, London

  • Smart LED lighting installation with presence/absence detection to cut energy costs linked to the AV system (AV works carried out by others)
  • Door access system altered to suit layout
  • Fire alarm installation installed to a category L2 throughout the office
  • Small power including floor boxes, underfloor busbar installation and various power outlets
  • Mechanical power installed to ensure air conditioning and ventilation needs were met
View More Photos

Client – Summit Therapeutics Ltd

Project Value – £50,000.00

Project Details – Complete design and build office refurbishment on Milton Park, Oxfordshire

  • LV panels and distribution equipment installed
  • LED lighting installation with presence/absence detection to cut energy costs
  • Audio visual installation that included ceiling projectors and remote control screens
  • Door access system installed to create a safe server room
  • Audio visual intercom system installed to link reception with the office area
  • Fire alarm installation installed to a category L2 throughout the office
  • Small power including floor boxes, underfloor busbar alterations and various power outlets
  • Mechanical power installed to ensure air conditioning and ventilation needs were met
View More Photos

Client – Infor (Barcelona Office)

Project Value – £120,000.00

Project Details – Refurbishment on the 3rd and 4th floor of a central Barcelona office

  • LED lighting installation with presence/absence detection to cut energy costs
  • Audio visual installation
  • Small power including floor boxes, underfloor busbar alterations and various power outlets
  • Mechanical power installed to ensure air conditioning and ventilation needs were met

 

View More Photos